Features of MALCOM MS-9C Solder Flux Controller
- Fully automatic control of solder flux density.
- Machine functions are managed through a computer.
- The electronic display shows flux density and temperature values.
- Equipped with a temperature compensation unit (converts to 20°C) and water content compensation (0% conversion).
- RS232C output port for data integration.
Specifications of MALCOM MS-9C Solder Flux Controller
- Density Measurement Range: 0.8000 to 0.9000 (switchable to 0.7500 to 0.8500)
- Density Accuracy: ±0.003
- Temperature Compensation for Density: Compensation unit (converts to 20°C)
- Water Content Compensation for Density: Converts to 0% water content
- Surface Level Control: Upper and lower limit: 5mm
- Solution Temperature Measurement Range: 0 to 50°C (PT temperature sensor)
- Temperature Accuracy: ±0.5°C
- Water Content Measurement Range: 0 to 9.9%
- Water Content Accuracy: ±1%
- Solution Supply Method: Automatic pump (1m, 500ml/min)
- Solution Cutoff: Buzzer, LED (red)
- Tank Capacity: 18 liters per tank
- Outputs:
- Digital: RS232C, B9600, C8, NP, S1
- Analog: DC4-20mA
- Sensor Cable Length: 3m
- Input: 6m
- Materials: Vinyl chloride, stainless steel, PE, PP, EPT, polyurethane, fluororubber, fluorocarbon, PA
- Operating Room Temperature: 10°C to 50°C
- Power Supply: AC100V (or AC200V), 50/60Hz
- Power Consumption: 35VA
- Fuse: 2A
- Weight: 11kg
>>> Learn more: List of