● RCX-GLseries Feature: |
・ You can freely add and configure the necessary functions (temperature measurement 6ch) core unit.
・ We have prepared a unit wind speed, oxygen concentration and temperature measurement camera 12ch required
to manage the reflow process.
・ Special program by the system, displayed on the screen the same oxygen concentration, wind speed camera
images.
・ The support functions in the profile condition is easy to create a profile.
・ For easy to obtaining and exchange, power supply is AAA battery.
・ in the wireless data transfer is possible to adopt a new BLUETOOTH.
● REFLOW CHECKER MEMORY UNIT (6 CHANNELS RCM-S): |
Feature
・Temperature measured in units of the underlying system.
・New features such as Bluetooth, OK/NG judgment function, Thermocouple response and AAA batteries.
Specification
Item | Specification |
Model Name | RCX-S |
Main Unit | RCM-S |
Measuring Temp. Range | 0~500℃ *1 |
Max Measuring Time | Approx. 10 hours * 1 * 2 |
Sampling Time (sec.) /Max. Storage Time | 0.05sec./4h50min, 0.1sec./10h40min, 0.2sec./21h20min, 0.5sec./48h20min,1.0sec/96h40min, 2.0sec./193h20min, 4.0sec/386h40min,8.0sec./773h20min Arbitrary setup possible |
Temperature Accuracy | ±1℃ |
Measuning Points | 1-6 Points |
Heat Resistant Connector | Miniature Connector |
Input | Thermocouple JIS-K 1kΩ max. |
0.1 10m | |
Power Supply | AAA battery |
Manganese batteries Alkaline battery Nickel-metal hydride | |
Outer dimensions | Memory unit (w/o Heat resistant case) 55 (W) x 170 (D) x 18 (H) mm 200g |
Heat resistant case: 65 (W) x 245 (D) x 25 (H) mm 370g | |
Data Transmission Method | USB, Bluetooth |
Weight | Approx. 570g (Heat resistant case and battery are included) |
* 1 It differes from the heat resistant time of memory unit.
* 2 It is the experimental value by AAA battery. The max. measuring time depens on battery capacity.
* The above specifications are subject to change without notice.
● REFLOW CHECKER MEMORY UNIT (PLUS α 6 CHANNELS RCM-T): |
Feature
・12ch measurement is possible by adding to RCM-S memory unit.
Specification
Item | Specification |
Model Name | RCX-T |
Main Unit | RCM-T |
Measuring Temp. Range | 0℃~500℃※1 |
Max Measuring Time | Approx. 3hours※1 |
Sampling Time (sec.) | 0.05, 0.1, 0.2, 0.5, 1.0, 2.0, 4.0, 8.0 |
Temperature Accuracy | ±1℃ |
Measuning Points | 1~12poionts |
Heat Resistant Connector | Miniature Connector |
Input | Thermocouple JIS-K 1KΩ max. (φ0.1 10m) |
Outer dimensions | Memory unit (w/o Heat resistant case) 55 (W) x 253 (D) x 18 (H) mm ※ 2 |
Heat resistant case: 65 (W) x 328 (D) x 25 (H) mm ※2 |
* 1 It differes from the heat resistant time of memory unit.
* 2 It is the experimental value by AAA battery. The max. measuring time depens on battery capacity.
* The above specifications are subject to change without notice.
● REFLOW CHECKER MEMORY UNIT (RCX-C): |
Feature
・Monitor a video of observation in the reflow oven.
・A removable carmera enables to obserrve from various angles.
Specification
Item | Specification |
Model Name | RCX-C |
Main Unit | RCM-C |
Camera | Separate type, Heat-resistant color camera |
Cable length | 50cm (scheduled) |
Moving image format | ASF (scheduled) |
Max Recording time | 10min (Battery and heat resistant time are not included) |
Outer dimensions | Camera unit : 44 (W) x 84 (D) x 19 (H) mm ※ 1 |
Heat resistant case: 65 (W) x 370 (D) x 25 (H) mm ※2 |
* 1 It differes from the heat resistant time of memory unit.
* 2 It is the experimental value by AAA battery. The max. measuring time depens on battery capacity.
* The above specifications are subject to change without notice.
● REFLOW CHECKER MEMORY UNIT (PLUS α O2 CONCENTRATION MONITOR RCM-O) : |
Feature
・Measure the oxygen concentration profile in the furnace.
Specification
Item | Specification | |
Model Name | RCX-O | |
Main Unit | RCM-O | |
Max. measuring time | Ni-MH battery: Approx. 40min. | |
Sampling time | 0.05sec. 0.1sec. 0.2sec. 0.5sec. 1.0sec. 2.0sec. 4.0sec. 8.0sec. | |
Arbitrary setup possible (synchronized to RCM-S memory unit) | ||
Oxygen | Measurement principle | Zirconia limiting current method |
Measurement range | 50ppm~5000ppm | |
Measurement accuracy | 50ppm~1000ppm±5%FS | |
1000ppm~5000ppm±10%FS | ||
Power supply | Supplied from RCM-S Memory unit | |
Ni-MH battery (AAA battery x 3) | ||
Outer dimensions | 65(W)×383(D)×25(H)(㎜) Excluding projections | |
Weight | Approx. 950g (including battery, tray is not included) |
* The maximum measuring time is a time in which heat resistance is not considered, and it cannot be measured
in the reflow oven.
* Manganese batteries and alkaline batteries are not available.
* Lithium-ion secondary battery or AAA battery is selectable at the time of order.
* The above specifications are subject to change without notice.
● REFLOW CHECKER MEMORY UNIT (PLUS α AIR VELOCITY MONITOR RCM-W) : |
Feature
・Measure the wind speed profile.
Specification
Item | Specification |
Model Name | RCX-W |
Main Unit | RCM-W |
Measurement accuracy | ±5% + 0.1m/s of the indicated value |
Sampling time (sec.) | 0.5 |
The number of measuring points | 1point |
Outer dimensions | Memory unit (w/o Heat resistant case): 55 (W) x 210 (D) x 18 (H) mm ※ 1 |
Heat resistant Case: 65 (W) x 245 (D) x 25 (H) mm ※2 |
* 1 It differes from the heat resistant time of memory unit.
* 2 It is the experimental value by AAA battery. The max. measuring time depens on battery capacity.
* The above specifications are subject to change without notice.